Skip to main navigation Skip to search Skip to main content

The FRESH Study: Treatment of Intracranial Aneurysms with the New FRED X Flow Diverter with Antithrombotic Surface Treatment Technology-First Multicenter Experience in 161 Patients

  • D. F. Vollherbst
  • , H Lücking
  • , J DuPlessis
  • , Michael Sonnberger
  • , C Maurer
  • , N Kocer
  • , M. Killer-Oberpfalzer
  • , R Rautio
  • , L Valvassori
  • , A Berlis
  • , Stefan Gasser
  • , S. Gatt
  • , A. Dörfler
  • , M. Bendszus
  • , M.A. Möhlenbruch*
  • *Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Background and purpose: Flow diverters with antithrombotic coatings are increasingly used to improve the safety of flow diverter treatments of intracranial aneurysms. This study aimed to investigate the safety and short-term efficacy of the new FRED X flow diverter. Materials and methods: Medical charts and procedural and imaging data of a consecutive series of patients with intracranial aneurysms who were treated with the FRED X at 9 international neurovascular centers were retrospectively analyzed. Results: One hundred sixty-one patients (77.6% women; mean age, 55 years) with 184 aneurysms (11.2% acutely ruptured) were included in this study. Most aneurysms were located in the anterior circulation (77.0%), most frequently at the ICA (72.7%). The FRED X was successfully implanted in all procedures. Additional coiling was performed in 29.8%. In-stent balloon angioplasty was necessary in 2.5%. The rate of major adverse events was 3.1%. Thrombotic events occurred in 7 patients (4.3%) with 4 intra- and 4 postprocedural in-stent thromboses, respectively (1 patient had both peri- and postprocedural thrombosis). Of these thrombotic events, only 2 (1.2%) led to major adverse events (ischemic strokes). Postinterventional neurologic morbidity and mortality were observed in 1.9% and 1.2%, respectively. The rate of complete aneurysm occlusion after a mean follow-up of 7.0 months was 66.0%. Conclusions: The new FRED X is a safe and feasible device for aneurysm treatment. In this retrospective multicenter study, the rate of thrombotic complications was low, and the short-term occlusion rates are satisfactory.
Original languageEnglish
Pages (from-to)474-480
Number of pages7
JournalAmerican Journal of Neuroradiology
Volume44
Issue number4
DOIs
Publication statusPublished - Apr 2023

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fields of science

  • 102003 Image processing
  • 102026 Virtual reality
  • 102037 Visualisation
  • 301102 Anatomy
  • 301409 Neuroanatomy
  • 302071 Radiology
  • 301103 Medical diagnostics
  • 301111 Radiologic anatomy
  • 301115 Sonoanatomy
  • 302013 Medical diagnostics
  • 303039 Radiological technology
  • 302 Clinical Medicine
  • 301 Medical-Theoretical Sciences, Pharmacy
  • 303 Health Sciences
  • 304 Medical Biotechnology
  • 302043 Magnetic resonance imaging (MRI)
  • 302010 Computed tomography (CT)
  • 305 Other Human Medicine, Health Sciences
  • 302070 Radiodiagnostics

JKU Focus areas

  • Digital Transformation

Cite this