Monitoring of the dilution of motor oil with Diesel using an advanced resonant sensor system

Research output: Chapter in Book/Report/Conference proceedingConference proceedingspeer-review

Abstract

In modern light-duty Diesel vehicles the particulate filters in the exhaust system require periodic regeneration to prevent plugging. The regeneration procedure is a major cause of dilution of engine oil with diesel fuel. In order to investigate the effect of the operation conditions of the engine on the fuel content in the oil, a precise and fast in-line measurement system is required. In this contribution a resonant sensor system for determination of diesel content by measuring the viscosity of the oil is tested. A commercial off-the-shelf quartz tuning fork resonator is used as sensor element and evaluated using a universal analyzer for resonant sensors developed for fast and precise acquisition of resonant sensor responses. The experiments presented in this paper show that fuel concentration in the range of 0.2 % can be determined within seconds. The obtained results are compared to that obtained with an accurate lab bench viscosity and mass density meter.
Original languageEnglish
Title of host publicationProceedings of the EUROSENSORS 2016
Number of pages4
Publication statusPublished - Sept 2016

Fields of science

  • 202021 Industrial electronics
  • 202036 Sensor systems
  • 203017 Micromechanics
  • 202 Electrical Engineering, Electronics, Information Engineering
  • 202027 Mechatronics
  • 202028 Microelectronics
  • 202037 Signal processing

JKU Focus areas

  • Mechatronics and Information Processing

Cite this