TY - JOUR
T1 - Extensive thoracoabdominal aortic electro septotomy: A case report of a novel approach in the treatment of chronic aortic dissections
AU - Huber, Florian
AU - Schachner, Bruno
AU - Hagleitner, Georg
AU - Binder, Ronald K
AU - Pichler, Peter
AU - Zierer, Andreas Florian
PY - 2024/1
Y1 - 2024/1
N2 - Treatment of post-dissection arch and thoracoabdominal aortic aneurysms presents significant therapeutic challenges. True lumen collapse or take off of aortic branches from the false lumen makes endograft alignment difficult, if not impossible. We present herein the first successful case of an extensive thoracoabdominal electro aortic septotomy of the entire dissection membrane from the aortic arch down to the aortic bifurcation during an open redo aortic arch replacement employing the frozen elephant trunk technique. The procedure was performed on a 59 years old female patient presenting with a progressive post-dissection aortic aneurysm during follow-up with a maximum diameter of 6 cm 11 years after operating on an acute type A aortic dissection. Due to the extensive longitudinal aortic electric septotomy, we created a new "common lumen" for subsequent endovascular completion of the repair.
AB - Treatment of post-dissection arch and thoracoabdominal aortic aneurysms presents significant therapeutic challenges. True lumen collapse or take off of aortic branches from the false lumen makes endograft alignment difficult, if not impossible. We present herein the first successful case of an extensive thoracoabdominal electro aortic septotomy of the entire dissection membrane from the aortic arch down to the aortic bifurcation during an open redo aortic arch replacement employing the frozen elephant trunk technique. The procedure was performed on a 59 years old female patient presenting with a progressive post-dissection aortic aneurysm during follow-up with a maximum diameter of 6 cm 11 years after operating on an acute type A aortic dissection. Due to the extensive longitudinal aortic electric septotomy, we created a new "common lumen" for subsequent endovascular completion of the repair.
UR - https://www.scopus.com/pages/publications/85182628525
U2 - 10.1177/2050313X231225867
DO - 10.1177/2050313X231225867
M3 - Article
SN - 2050-313X
VL - 12
JO - SAGE Open Medical Case Reports
JF - SAGE Open Medical Case Reports
ER -