N2 - Nowadays, surgical treatment of cerebral aneurysms remains one of the most demanding disciplines in neurosurgery. The increasing shift toward endovascular interventions leads to a decline in open surgical cases. This fact leaves residents and young neurosurgeons with fewer training opportunities and limited to complex and high-risk aneurysms. There is a growing need for realistic simulation tools to enhance neurosurgical training and preoperative planning. We developed and externally validated a patient-specific mixed-reality simulator for cerebral aneurysm clipping, during the research project "Medical EDUcation in Surgical Aneurysm Clipping (MEDUSA)". Our approach combines physical phantoms of the skull and brain tissue with virtual intracranial blood vessels, including a virtual intracranial aneurysm. Real surgical instruments provide an immersive training environment featuring integrated blood flow simulation for evaluating clipping strategies. A life-sized skull with silicone brain lobes is mounted in a standard neurosurgical head clamp. Optical tracking synchronizes the position of a real clip applier and an emulated surgical microscope with the corresponding virtual environment, allowing true mixed-reality interaction. After aneurysm clipping, blood flow is automatically simulated to assess residual aneurysms or stenoses of the parental vessels. We conducted an external validation with 40 neurosurgeons at two international events. Participants completed a 32-item questionnaire evaluating face and content validity on a 5-point Likert scale. Participants' surgical experience ranged from novice to expert (> 15 years). Average ratings for simulator realism and educational value were high, with mean scores between 3.13 and 4.25. The highest ratings were for the blood flow simulation (4.25) and the simulator's potential for preoperative planning (4.20). Most participants agreed that the physical and virtual components were valuable and that the simulator should be integrated into neurosurgical training and standard surgical workflows. Our mixed-reality simulator achieved robust face and content validity among a diverse group of neurosurgeons. Combining real surgical instruments with a deformable virtual aneurysm model, including blood flow simulation, offers a high level of realism and immediate objective feedback.
AB - Nowadays, surgical treatment of cerebral aneurysms remains one of the most demanding disciplines in neurosurgery. The increasing shift toward endovascular interventions leads to a decline in open surgical cases. This fact leaves residents and young neurosurgeons with fewer training opportunities and limited to complex and high-risk aneurysms. There is a growing need for realistic simulation tools to enhance neurosurgical training and preoperative planning. We developed and externally validated a patient-specific mixed-reality simulator for cerebral aneurysm clipping, during the research project "Medical EDUcation in Surgical Aneurysm Clipping (MEDUSA)". Our approach combines physical phantoms of the skull and brain tissue with virtual intracranial blood vessels, including a virtual intracranial aneurysm. Real surgical instruments provide an immersive training environment featuring integrated blood flow simulation for evaluating clipping strategies. A life-sized skull with silicone brain lobes is mounted in a standard neurosurgical head clamp. Optical tracking synchronizes the position of a real clip applier and an emulated surgical microscope with the corresponding virtual environment, allowing true mixed-reality interaction. After aneurysm clipping, blood flow is automatically simulated to assess residual aneurysms or stenoses of the parental vessels. We conducted an external validation with 40 neurosurgeons at two international events. Participants completed a 32-item questionnaire evaluating face and content validity on a 5-point Likert scale. Participants' surgical experience ranged from novice to expert (> 15 years). Average ratings for simulator realism and educational value were high, with mean scores between 3.13 and 4.25. The highest ratings were for the blood flow simulation (4.25) and the simulator's potential for preoperative planning (4.20). Most participants agreed that the physical and virtual components were valuable and that the simulator should be integrated into neurosurgical training and standard surgical workflows. Our mixed-reality simulator achieved robust face and content validity among a diverse group of neurosurgeons. Combining real surgical instruments with a deformable virtual aneurysm model, including blood flow simulation, offers a high level of realism and immediate objective feedback.
KW - Humans
KW - Intracranial Aneurysm/surgery
KW - Neurosurgical Procedures/education
KW - Surgical Instruments
KW - Computer Simulation
KW - Neurosurgeons/education
KW - Virtual Reality
KW - Simulation Training/methods
KW - Male
KW - Clinical Competence
UR - https://www.scopus.com/pages/publications/105018293010
U2 - 10.1007/s10143-025-03846-x
DO - 10.1007/s10143-025-03846-x
M3 - Article
C2 - 41062869
SN - 0344-5607
VL - 48
JO - Neurosurgical review
JF - Neurosurgical review
IS - 1
M1 - 686
ER -