Skip to main navigation Skip to search Skip to main content

Comparison of Two and Four Pole Rotors for a High Speed Bearingless Drive

Research output: Chapter in Book/Report/Conference proceeding › Conference proceedings › peer-review

Abstract

Bearingless drives have found their way into several industrial applications such as pumps, fans and chemical process chambers. In contrast to these drives which run at speeds below 15.000rpm, the suitability of bearingless drives for high speed has first been demonstrated with a bearingless disk drive running up to 115.000rpm in previous works by the authors. This drive uses a permanent magnet rotor with a pole number of two in order to constrain iron losses and generate the highest rotor speed with a certain electrical frequency. Other certain criteria such as the rotordynamic behaviour, the radial bearing force or the torque capacity, however, might benefit from a higher pole number. Therefore, this paper will present the comparison of a two-pole rotor for the use in a hgh speed bearingless drive.
Original languageEnglish
Title of host publicationISMB 2012, The 13th International Symposium on Magnetic Bearings, Arlington, Virginia, USA
Number of pages11
Publication statusPublished - Aug 2012

Fields of science

  • 202009 Electrical drive engineering
  • 202011 Electrical machines
  • 202034 Control engineering
  • 202021 Industrial electronics
  • 202027 Mechatronics

JKU Focus areas

  • Mechatronics and Information Processing

Cite this