Anterior Chamber Depth and IOL Calculations.

Oliver Findl, Nino Hirnschall, Martin Kronschläger

Research output: Chapter in Book/Report/Conference proceedingChapterpeer-review

Abstract

The accurate prediction of postoperative anterior chamber depth (ACD) (intraocular lens (IOL) position) is important for accurate IOL power calculation. Different means to predict the postoperative ACD are discussed. Some of them are based on preoperative biometric measurements, while others can use intraoperative optical coherence tomography measurements of aphakic ACD. Whatever method is used the postoperative shift in ACD should be taken into account and possible factors like rhexis size, centering, and shape as well as patient factors such as zonule integrity and capsular shrinkage may also have an effect.
Original languageEnglish
Title of host publicationIntraocula Lens Calculations.
Editors Arun. D. Singh
PublisherSpringer
Pages537-550
Number of pages13
ISBN (Print)978-3-031-50665-9
DOIs
Publication statusPublished - 2024

Fields of science

  • 302007 Ophthalmology