Accuracy Considerations and FMCW Operation of a Six-Port Device

Research output: Chapter in Book/Report/Conference proceedingConference proceedingspeer-review

Abstract

The application of a six-port device in a frequency modulated continuous wave sensor system is presented. Two completely different modes of operation are combined in the distance sensor to achieve an outstanding performance. A frequency sweep is accomplished and evaluated using the uncalibrated six-port device without degrading the final distance accuracy. The latter accuracy is determined by the phase measurement accuracy of the calibrated six-port operating at 35 GHz. Influences of the six-port parameters with respect to the phase accuracy are treated.
Original languageEnglish
Title of host publicationProceedings of 2001 Asia Pacific Microwave Conference (APMC 2001)
Number of pages4
Publication statusPublished - Dec 2001

Fields of science

  • 202 Electrical Engineering, Electronics, Information Engineering
  • 202019 High frequency engineering
  • 202021 Industrial electronics
  • 202027 Mechatronics
  • 202028 Microelectronics
  • 202036 Sensor systems
  • 202037 Signal processing
  • 203017 Micromechanics
  • 502058 Digital transformation

Cite this