Accuracy Analysis of Six-Port Devices

Christian Diskus, Andreas Stelzer

Research output: Chapter in Book/Report/Conference proceedingConference proceedingspeer-review

Abstract

In this contribution the various influences on the accuracy of a six-port device are investigated. The actual design operates at 34-36.2 GHz. To achieve a highly accurate phase measurement, attention must be paid to various error sources. As a result of these investigations a highly accurate six-port was designed and applied to a precision distance sensor. The realized six-port exhibits a phase error of three degrees. The overall distance accuracy of the system is ?0.1 mm.
Original languageEnglish
Title of host publicationProceedings of the 8th International Symposium on Microwave and Optical Technology (ISMOT 2001)
Number of pages6
Publication statusPublished - Jun 2001

Fields of science

  • 202 Electrical Engineering, Electronics, Information Engineering
  • 202019 High frequency engineering
  • 202021 Industrial electronics
  • 202027 Mechatronics
  • 202028 Microelectronics
  • 202036 Sensor systems
  • 202037 Signal processing
  • 203017 Micromechanics
  • 502058 Digital transformation