PDMS Membrane with Integrated Nozzle-Diffuser Structure for Peristaltic Pumping of Fluids in Microfluidic Structures

Activity: Talk or presentationContributed talkunknown

Description

In this contribution we present a concept, where a tiny nozzle-diffuser structure is directly integrated into the center of a flexible poly(dimethylsiloxane) (PDMS) membrane, which is placed into a small fluid cavity with symmetric inlet and outlet geometry. The actuation of the membrane is achieved with an electromagnetic coil from the outside and a small magnetic ring, which has also been integrated into the membrane. The sinusoidal excitation leads to a vibrational movement of the membrane in the fluid cavity, and due to the asymmetric hydrodynamic resistance of the cone-shaped opening in the center of the membrane, which essentially resembles a nozzle-diffuser structure, a unidirectional fluid flow evolves in the system. This pump mechanism can be further miniaturized and integrated into microfluidic systems. In this paper we present details on the device concept, we report on the fabrication procedure, and we show experimental results with a first functional prototype.
Period11 Dec 2014
Event titleMicrofluidics 2014
Event typeConference
LocationIrelandShow on map

Fields of science

  • 202028 Microelectronics
  • 202027 Mechatronics
  • 202037 Signal processing
  • 202036 Sensor systems
  • 202 Electrical Engineering, Electronics, Information Engineering
  • 202021 Industrial electronics
  • 203017 Micromechanics
  • 202019 High frequency engineering

JKU Focus areas

  • Mechatronics and Information Processing