Optimal parameter estimation method for different types of resonant liquid sensors

Activity: Talk or presentationContributed talkunknown

Description

The performance of a recently introduced method to estimate the resonance parameters from complex spectral data and the error propagation for viscosity and density parameters of liquids are examined. The method is known to produce excellent results when used for piezoelectric and Lorentz force actuated sensors for single port or two-port devices. The method is also suited for very low quality factors (< 10) which extends the usable measurement range of many sensor concepts, especially for fluid sensing applications. Generally valid expressions for the measurement accuracy are stated and compared to measurement results obtained with a piezoelectric tuning fork and a Lorentz force actuated and inductively read out platelet sensor.
Period10 Sept 2014
Event titleunbekannt/unknown
Event typeConference
LocationItalyShow on map

Fields of science

  • 202028 Microelectronics
  • 202027 Mechatronics
  • 202037 Signal processing
  • 202036 Sensor systems
  • 202 Electrical Engineering, Electronics, Information Engineering
  • 202021 Industrial electronics
  • 203017 Micromechanics
  • 202019 High frequency engineering

JKU Focus areas

  • Mechatronics and Information Processing