Efficient Frequency-domain Evaluation of Transient Voltage Effects in Electric Machines

  • Bianca Wex (Speaker)

Activity: Talk or presentationContributed talkscience-to-science

Description

The use of wide bandgap semiconductors in inverters such as SiC and GaN can lead to very high voltage transients in electric machines, causing severe voltage stress on the isolation system and possibly electromagnetic compatibility (EMC) issues. In order to model the influence of steep voltage steps on stator windings a high-frequency multi-turn model of an electric machine is created. The parameters for the electrical network including their frequency dependency are determined analytically or via 2D finite elemente method (FEM). Furthermore, a state-space model of the electrical network is extracted. Since the model is evaluated analytically in the frequency domain, this method is computationally efficient and more flexible than conventional approaches that use network analysis software such as SPICE. First measurements of transient voltage effects are performed for a 3-phase 23 kW permanent magnet synchronous machine supplied by an inverter with 276 V DC-link voltage at 12 kHz, validating the proposed simulation method.
Period16 May 2022
Event titleIPEC2022 ECCE Asia, 15.-19-05.2022, Himeji, Japan
Event typeConference
LocationAustriaShow on map

Fields of science

  • 202027 Mechatronics
  • 202025 Power electronics
  • 202 Electrical Engineering, Electronics, Information Engineering
  • 202011 Electrical machines
  • 202009 Electrical drive engineering

JKU Focus areas

  • Digital Transformation
  • Sustainable Development: Responsible Technologies and Management