Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Development of dispersion layers for dental drills with reduced Nickel release

  • Florian Pfaffeneder-Mantai
  • , Cezarina Cela Mardare
  • , Dritan Turhani
  • , Achim Walter Hassel
  • , Christoph Kleber

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

Abstract

Objectives: Without rotating instruments, for example diamond-coated drills with a core made of stainless steel, the dental routine would be unimaginable, since these are used in almost every dental activity and are thus indispensable for the professional practice. Unfortunately, such drills release Nickel particles to a high content into the cooling water of the drill. Values up to 1.3 mg/l Nickel were found by ICP – OES in the cooling water of the drillers which is of course also transferred into the patient’s oral cavity with possible severe negative effects. Therefore, novel plating procedures have to be developed to increase the patients (and dentists) safety during treatment. Methods: Dispersion layers with the hard metal Tungsten carbide (WC) particles on stainless steel blanks were deposited following two synthesis routines (i) Plasma-Electrolytic Oxidation (PEO) and (ii) galvanic plating out of a Watts bath. Both were accomplished using water-based electrolytes. Results: In order to verify the dental applicability of the developed coatings, tests-drills were accomplished under defined conditions on plastic teeth for the sake of reproducibility. Commercially produced drills were compared with the newly plated ones by Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM) and the drilling cooling water was examined for heavy metal residues using Inductively Coupled Plasma (ICP) analytics. The resulting grinding patterns in the plastic teeth were investigated by light microscopy and SEM. It could be shown that dispersion layers plated by a galvanic procedure showed a reduced Nickel release compared to a commercial driller by factor 7.6 and 13.4 compared to PEO plated ones during dental treatments. Conclusions: Following the clinical significance the Watts bath plated drillers showed a better WC particle distribution on the surface and better abrasive properties during the drilling experiments compared to PEO plated drillers. In addition the Nickel release during dental use is much less from the galvanic treated ones. By optimising the plating condition from the Watts dispersion bath further novel drilling devices with significantly reduced release of Nickel particles can be developed for the benefit of the patients.
OriginalspracheEnglisch
Aufsatznummer100045
Seiten (von - bis)100045
Seitenumfang7
FachzeitschriftPhysics in Medicine
Volume12
DOIs
PublikationsstatusVeröffentlicht - Dez. 2021

Wissenschaftszweige

  • 204 Chemische Verfahrenstechnik
  • 205016 Werkstoffprüfung
  • 210006 Nanotechnologie
  • 104014 Oberflächenchemie
  • 105113 Kristallographie
  • 105116 Mineralogie
  • 204001 Anorganisch-chemische Technologie
  • 211104 Metallurgie
  • 104005 Elektrochemie
  • 104006 Festkörperchemie
  • 104017 Physikalische Chemie
  • 503013 Fachdidaktik Naturwissenschaften

JKU-Schwerpunkte

  • Sustainable Development: Responsible Technologies and Management

Dieses zitieren