Anterior Chamber Depth and IOL Calculations.

Publikation: Beitrag in Buch/Bericht/KonferenzbandKapitelBegutachtung

Abstract

The accurate prediction of postoperative anterior chamber depth (ACD) (intraocular lens (IOL) position) is important for accurate IOL power calculation. Different means to predict the postoperative ACD are discussed. Some of them are based on preoperative biometric measurements, while others can use intraoperative optical coherence tomography measurements of aphakic ACD. Whatever method is used the postoperative shift in ACD should be taken into account and possible factors like rhexis size, centering, and shape as well as patient factors such as zonule integrity and capsular shrinkage may also have an effect.
OriginalspracheEnglisch
TitelIntraocula Lens Calculations.
Herausgeber*innen Arun. D. Singh
VerlagSpringer
Seiten537-550
Seitenumfang13
ISBN (Print)978-3-031-50665-9
DOIs
PublikationsstatusVeröffentlicht - 2024

Wissenschaftszweige

  • 302007 Augenheilkunde

Dieses zitieren