Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

An analysis pipeline for detecting copy number variations with a low false discovery rate in microarray data

Publikation: Beitrag in Buch/Bericht/KonferenzbandKonferenzbeitragBegutachtung

Abstract

A low false discovery rate (FDR) at the detection of copynumber aberrations (CNAs) in microarray data ensures sufficient detection power and prevents failures in CNA-disease association studies. A high FDR means many falsely discovered aberrations, which are not associated with the disease, though correction for multiple testing must take them into account. Thus, a high FDR not only decreases the discovery power of studies but also the significance level of the remaining discoveries after correction for multiple testing. Methods: We obtain a low FDR at the detection of CNAs in microarray data by a probabilistic latent variable model, called “cn.FARMS”. The model is optimized by Bayesian maximum a posteriori approach, where a Laplace prior prefers models, which represent the null hypothesis of observing a constant copy number 2 for all samples. The posterior can only deviate from this prior by strong (deviation from copy number 2 intensities) and consistent signals in the data, which hints at a CNA - the alternative hypothesis. The information gain of the posterior over the prior gives the informative/non-informative (I/NI) call that serves as a filter for CNA candidate regions. I/NI call filtering reduces the FDR, because a region with a large I/NI call is unlikely to be a falsely detected CNA, which would neither have strong nor consistent measurements. It can be shown that the I/NI call filter applied to null hypotheses of the association study is independent of the test statistic which in turn guarantees that a type I error rate control by correction for multiple testing is still possible after filtering. I/NI-calls perform well for the usually rare CNAs that are seen at few samples only, where variance-based filtering approaches fail. Results: cn.FARMS clearly outperformed prevalent methods for CNA detection with respect to sensitivity and especially with respect to FDR on different HapMap benchmark data sets.
OriginalspracheEnglisch
Titel12th International Congress of Human Genetics and the American Society of Human Genetics
Seitenumfang1
PublikationsstatusVeröffentlicht - Okt. 2011

Wissenschaftszweige

  • 106013 Genetik
  • 106041 Strukturbiologie
  • 102 Informatik
  • 101029 Mathematische Statistik
  • 102001 Artificial Intelligence
  • 101004 Biomathematik
  • 102015 Informationssysteme
  • 102018 Künstliche Neuronale Netze
  • 106002 Biochemie
  • 106023 Molekularbiologie
  • 305 Andere Humanmedizin, Gesundheitswissenschaften
  • 106005 Bioinformatik

Dieses zitieren